Hello Rickard, issue here could be the place you added the parameter in SICF? This is from viewing the lasts screenshot. Start transaction SICF Open the corresponding tree nodes for the service you would like to modify i.e webgui > default host ->sap -> bc -> gui -> sap -> its -> webgui Select 'Test service' from context menu of the service node i.e: Right Click -> Test Service This will launch the 'webgui' service in the browser - from here logon to system again. If you call transaction VA01 from here and are are able to reproduce the issue - this this is where the paramater should be set in SICF > default host ->sap -> bc -> gui -> sap -> its -> webgui -> 'GUI Configuration and NOT 'default host'. In the integrated ITS we have new procedures for activating services and their templates. This article describes these steps as a quick start tutorial. Service data in the integrated ITS A service running in the integrated ITS consists of three major parts, an ICF service, templates containing the Business HTML, and the MIME data for icons, cascading style sheets, javascript files etc. All of this service data are maintained as an Internet Service in the transaction SE80. With the standalone ITS the so called IACOR (Internet Application Component Object Receiver) was used for publishing such a service to the ITS. ![]() After having published the data the service can be used. This has changed with the integrated ITS. Service Definition Though Internet Services are created in the transaction SE80, they must be defined using the transaction SICF too. Service parameters must be defined in SICF for being effective in the integrated ITS. Service Parameters Though service parameters can be maintained within the SE80, they must be configured in the ICF service description. There is no possibility for publishing the parameters to an ICF service. However, it is not a big task to create and configure an ICF service. ![]() ICF services are created, configured, and maintained using the transaction SICF. A good starting point is to study some of the ITS services that SAP delivers with the WebAS. Those examples are /sap/bc/gui/its/webgui and /sap/bc/gui/its/test/it/it00. ICF services have to be activated before they can be used. This task can also be done with transaction SICF. Business HTML Templates and MIME data Publishing the templates and the MIME data is an easy task in the transaction SE80. Choose the Internet Service to be published, make sure that your workbench settings for the ITS is 'integrated ITS' - older versions of the dialog offer a site called 'INTERNAL'. Use 'Menu'=>'Utilities'=>'Settings' for maintaining the publishing target. Activate the service webgui. To activate the SAP WebGui service, activate the node: /sap/bc/gui/sap/its/webgui. Activation of public resources. Hi,I need to activate teh Web access fro SAP Ecc. I presume you're talking about Webgui. If i activate web access. Just enable the service in SICF and. How to activate, publish and test ITS services in the integrated ITS. Service data in the. Those examples are /sap/bc/gui/its/webgui and /sap/bc/gui/its/test. The figures below show the dialog for a WebAS 640 and a newer release resp. Mark the service in the tree and use the context menu for publishing the whole service. Screenshot of 6.40: Screenshot of 7.00 and higher: Testing the service The service can be tested in the transaction SICF. Just use the context menu and choose 'test service'. A browser window with the correct URL will appear. As an alternative the function module SITSP_GET_URL can be used for retrieving the URL. Running your first ITS WebGUI application in SAP NetWeaver 04 ABAP Edition See also the SAP NOTE ITS 700 preclarification and basic problem analysis.
0 Comments
How to transfer my mobile number You’ve got a new phone or SIM card but want to keep your old mobile number - that's not much to ask for, really, is it? Don’t worry, it’s a fairly simple process. Here’s everything you need to know about keeping your number when you change your contract or SIM card - even if you're joining a new network. What do I need to keep my number? ![]() You’ll need a PAC (Porting Authorisation Code - sometimes called a 'PAC code'). This is a number that lets you transfer your current number to your new SIM card. You need to get this from your. Do I always need a PAC? No, not always. If you’re staying with your current network, you’ll need a PAC if you’re upgrading from a deal to a one. If you’re upgrading from one Pay Monthly contract to another, or upgrading from a PAYG phone to another, you don’t need a PAC. Your number will automatically be activated on your new SIM. If you’re moving from one network to another, you’ll need a PAC. How do I get my PAC code? Call your current network and ask for your PAC. It’s free to get your PAC, and your network has to give you one within two days, or tell you why they can’t. ![]() You need to get your PAC before you disconnect your old SIM. If you don’t, you won’t be able to transfer your number. What do I do with my PAC? When you’re buying your new phone, tell the in-store colleague, or the staff member on the other end of the phone, that you want to keep your number. They'll normally ask for your PAC then, so if you have it already, that will make everything move quicker. Your PAC is valid for 30 days, so you have plenty of time to use it, but try to use your PAC as soon as possible. Can I use my PAC after I've bought my new phone? Yes, you can, but not if you’ve bought a deal from Talkmobile as the PAC needs to be used at the checkout for this network. For all other networks, call them up with your PAC code and they’ll be able to transfer your number to your new deal. Make sure you contact them before your SIM has been disconnected. How long will it take to transfer my number? Normally just two working days, but it can take a little longer in certain circumstances. If you give your PAC code to Carphone Warehouse, we’ll transfer your number within two working days of your new phone being connected. ![]() ![]() If you give your PAC code to your network, the amount of time it takes to transfer your number can vary. Still looking for your next device? Check out all right here, and for - follow the link. If you’ve got any more questions about how to keep your mobile number, leave a message in the comments and we’ll get back to you. If you're having trouble connecting to your network or sending MMS messages, these APN settings for O2 should help. As you go SIM cards. The settings shown here are for O2 contract SIM cards, and options for PAYG SIMs are shown in brackets. Press and hold the network name, o2 Internet and choose Activate. Activating your sim. Pay Monthly customers If you're new to O2, your sim is ready to use straightaway. Just pop it in your device and you're good to go. Pay Monthly customers. If you're new to O2, your sim is ready to use straightaway. Pay As You Go customers. If you're new to O2 and you have a Pay As You Go sim, you'll need to top up to activate it. Existing customers. If you're already an O2 customer and you've upgraded your device, you might need a different sized. Find good activator for Windows is not easy. Sometimes, activation drops, and black screen appears. This activator of Chew-WGA, activates Windows 7 only need to download and run. Black screen windows 7 and as we can see at the bottom inscription – Your copy of Windows is not genuine / assembly 7601 Your copy of Windows 7 is not genuine. So, after the appearance of these trouble, the majority of Windows activators powerless. But the way to resolve this problem exists! Follow all actions in this list and you will be happy. ![]() Instructions: • Download the activator Windows7 ( Password for archive – windows). • Run CW.EXE, click Apply (After system reboots, Windows will be activated). Do you want to download chewwga-0-9.zip right now? Size: 9 MB Downloads: 429274 Video instruction for activation: What to do if activation did not help? • Control panel. • Remove Programs. ![]() • View installed updates. • Remove Update for Microsoft Windows (KB971033). • Control Panel – Homepage. • System and security. Nov 19, 2017 How to Activate Windows 7. While Windows is typically set to activate automatically when you install it, you may find a time when you need to manually activate it. Dec 17, 2016. So, after the appearance of these trouble, the majority of Windows activators powerless. But the way to resolve this problem exists! Follow all actions in this list and you will be happy. Instructions: Download the activator Windows7 (Password for archive – windows). Run CW.EXE, click Apply (After system. Download the best activator for Windows 7 – Chew – WGA. Instructions: Download the Windows7 activator (Password for archive – windows). Run CW.EXE, click Apply (After system reboot, Windows will be activated). The key for Windows 7 Ultimate (who needs). Do you want to. With its modern features and equipment, a user can activate window 7 without any problem. After activate the Windows 7 loader free download full version you can update the system at any time. Window 7 loader just work on one click. Window 7 Loader activator free download is technically very efficient. ![]() ![]() • Enable or disable automatic updates. • Control Panel – Homepage / Administration. • Software protection / Stop. • Software Protection. • Open any folder (My Computer, for example), and set the visibility of hidden files (required). • In the search box insert.C7483456-A289-439d-8115-601632D005A0 and remove two found files (if not removes (if not works, the system uses, repeat paragraph 10 ). • Again we go in services (paragraphs 8 and 9), but now torn on “Software Protection”. • Download the Windows7 activator. • Run CW.EXE, click Apply (After system reboot, Windows will be activated). If you do not have KB971033 or files from 12 paragraph, then just continue with the actions. Screenshots of activated Windows 7 sp1. Thanks again, John J (via e-mail) A: Good to hear from you, John. You are correct that if the ambient temperature changes drastically it can cause the TPMS light to come on. One thing to check before you get started is the Drivers Information Center (DIC). Scroll through to see if all of the TPMS sensors are reading some kind of air pressure. A sensor may be defective if it reads: “-.” Simple Procedure When the TPMS light comes on there is a simple procedure to reset the system that will work most of the time. A) First, adjust the air pressure to the factory specification. The factory specification is located on a sticker on the inside of the driver-side door or doorjamb. When filling the tires, start with the driver front tire, then the passenger front tire, then the passenger rear tire and finally the driver rear tire. B) Some vehicles require that you then drive the vehicle over 40 miles per hour for about a minute. C) If the TPMS is still on, raise the tire pressure in all four tires by 10 psi starting with the driver front tire, then the passenger front tire, then the passenger rear tire and finally the driver rear tire. D) Again, you may need to drive the vehicle over 40 miles per hour for about a minute. Normally this will reset the TPMS light, especially if the light came on due to ambient temperature. E) If the light reset, you will need to adjust the air pressure back to the factory specification starting with the driver front tire, then the passenger front tire, then the passenger rear tire and finally the driver rear tire. Types of TPMS Systems Used on Corvettes There are two types of TPMS: indirect and direct. Indirect systems use the vehicle’s wheel sensors to compare the turning circumference of each tire to the other three. This system is not very accurate and will not issue a warning if all four tires lose air equally, which can happen with temperature changes. 2/4 The direct system, which is used in the Corvette, uses sensors fitted inside the tire’s air chamber where they read the pressure directly. The early C4 systems used a transmitting wheel sensor, which is held in place by large band clamp. The C5 and newer Corvettes use a transmitting wheel sensor, which is attached to the tire’s valve stem. The tire pressure monitoring system (TPMS) has a separate sensor/transmitter in each wheel. If tires are rotated, a sensor is replaced or the sensor system simply loses its calibration, the TPMS warning light may illuminate. At this point, the receiver must be reprogrammed. Reprogramming the receiver is something you can do on most earlier Corvettes without the use of an expensive piece of equipment. Relearn Procedure 1991-1996 Corvette a) Ensure all of the tires are inflated to the factory specification listed on the doorjamb placard. B) When the ignition is turned off, the system will clear itself and the TPMS telltale will turn off. C) The system will recalibrate when the vehicle is operated at a speed of 30 mph for a minimum of 30 seconds. 1997-2004 Corvette General Motors has a special programming tool for this job (PN J41760), which is a U-shaped magnet. However, a large speaker magnet will usually do the job. 3/4 The following is a step-by-step procedure that anyone can do to reprogram the C5 Corvette’s wheel sensors: a) Ensure all of the tires are inflated to the factory specification listed on the doorjamb placard. B) Let the vehicle sit for 2 minutes, then turn the ignition to the Run position (engine off). C) Press the “Reset” button to clear any Instrument Panel Cluster (IPC) or DIC display warning messages. D) Press and release the “Options” button on the Information Center and scroll through the display options until the display is blank. E) Press and hold the Information Center “Reset” button for 3 seconds. F) Press the “Options” button again until the “TIRE TRAINING” message appears. G) Press the “Reset” button until the following message appears on the Information Center: “Learn Left Front Tire.” h) Place a large magnet over the left (driver-side) front valve stem. The horn will sound indicating the left front TPMS sensor is programmed. If this takes more than 15 seconds, pull the magnet back and try again, it will give you three tries. If the procedure fails after three tries then you must start the complete sequence over. I) When the horn sounds, the Information Center will direct you to proceed to program the next sensor in the following order: Learn Right Front Tire, Learn Right Rear Tire and Learn Left Rear Tire. The programming can be canceled at any time by turning the ignition off. If the programming is cancelled with less than four sensors learned, it will only accept the sensors programmed up to that point. 2005-’13 Corvette, With Standard Ignition (Tool Required) a) Let the vehicle sit for 2 minutes, then turn the ignition to the Run position (engine off). B) Using the keyless entry system; press and hold the lock and unlock buttons simultaneously until the horn chirps. Then the left front turn signal will become illuminated to let you know the learn mode is enabled. C) Install the wheel sensor reprogramming tool over the left front valve stem (you will need to hold the tool very close). The horn will sound, indicating the left front TPMS sensor is programmed. ![]() ![]() If this takes more than 15 seconds, pull the reprogramming tool back and try again, it will give you three tries. If the procedure fails after three tries then, you must start the complete sequence over. D) If the tool will not read a sensor, that sensor may have failed internally. E) When the horn sounds, the IPC will direct you to proceed to program the next sensor in the following order: Learn Right Front Tire, Learn Right Rear Tire and Learn Left Rear Tire. The programming can be canceled at any time by turning ignition off. If the programming is cancelled with less than four sensors learned, it will only accept the sensors programmed up to that point. F) After programing the last wheel sensor the horn will chirp twice to let you know all the sensors have been programed. 4/4 2005-’13 Corvette, With Pushbutton Start (Tool Required) a) Let the vehicle sit for 2 minutes, then turn ignition to the Run position (engine off). B) Press and hold the pushbutton start until the vehicle goes into accessary mode. C) Press the MENU button located on the turn signal lever until Vehicle Information Menu (VIM) is displayed. D) Once you are in the Vehicle Information Menu use the arrow up and arrow down buttons on the turn signal lever until the Drivers Information Center displays the tire pressure and position. E) Press and hold the button located on the end of the turn signal lever until the message “Are You Sure You Want to Relearn Yes or No” is displayed. F) Use the arrow up and arrow down buttons to highlight “Yes.” Press the button on the end of the turn signal lever and the horn will chirp. G) The tire learning active will be displayed on the DIC and the left front turn signal will be illuminated. H) Place the wheel sensor reprogramming tool over the left front valve stem (you will need to hold the tool very close). The horn will sound, indicating the left front TPMS sensor is programmed. If this takes more than 15 seconds, pull the reprogramming tool back and try again, it will give you three tries. Your tire pressure monitoring system acts as a safeguard, alerting you to waning tire pressure and helping to avoid placing you and your passengers in an unsafe situation. The TIA Tire Pressure Monitoring System (TPMS) Relearn Chart serves as a valuable. Triggering protocol or you may simply activate the tool and allow the. If the procedure fails after three tries then, you must start the complete sequence over. I) If the tool will not read a sensor, that sensor may have failed internally. J) When the horn sounds, the IPC will direct you to proceed to program the next sensor in the following order: Learn Right Front Tire, Learn Right Rear Tire and Learn Left Rear Tire. The programming can be canceled at any time by turning ignition off. If the programming is cancelled with less than four sensors learned, it will only accept the sensors programmed up to that point. K) After programing the last wheel sensor, the horn will chirp twice to let you know all the sensors have been programed. Note: some tire scan tools have the ability to place the vehicle in learn mode through the OBD-II connection. John, I hope this helps to keep that pesky TPMS light off. I know that light can be a problem, but I feel this is a great safety system to let drivers know when there may be a potential problem. Hope to see you again at one of the Corvette meets or at the auctions. Close (X) Buy 3 Tires, Get 4th Tire Free Instantly Buy 3 Tires, Get 4th Tire Free Instantly. Receive a discount equal to the price of a single tire when four tires are added to the cart. Valid on select in stock tires only. Those tires for which discount is available will be identified in search results & product detail pages. All other tires and special order tires are excluded from this offer. Valid when scheduled for installation on PepBoys.com and installation is completed between 11/28/17 through 12/31/17. Buy 3 Tires, Get 4th Tire Free Instantly Buy 3 Tires, Get 4th Tire Free Instantly. Receive a discount equal to the price of a single tire when four tires are added to the cart. Valid on select in stock tires only. Those tires for which discount is available will be identified in search results & product detail pages. All other tires and special order tires are excluded from this offer. Valid when scheduled for installation on PepBoys.com and installation is completed between 11/28/17 through 12/31/17. • > • / • / • TPMS (Tire Pressure Monitoring System) Services. ![]() Activating Bluetooth inside your car is easy, and all you need to remember is a little number called zero. Actually, you need to remember it 4 times — Best Buy has answers. The Best Buy Mobile team explains how simple it is to activate Bluetooth settings on an Android cell phone. Rusty: 'Hi, I'm Rusty, I'm. Using your Bluetooth-enabled cell phone as a modem for Internet access on your laptop is great in a pinch when there's no Wi-Fi service available or your regular internet service goes down. The main benefit of using Bluetooth instead of a USB cable for is that you can keep your in your bag or pocket and still make the connection. Here are instructions for using your phone as a Bluetooth modem, based on both and information from the, a trade association of companies associated with Bluetooth products. ![]() Note: There are two alternatives to this method, including using and your wireless provider's login information to tether your phone to your computer. The easiest route, however, may be to use or for regular phones, because these apps don't require you to make many settings changes or know specifics about your provider's technology. All you need is your Bluetooth phone and your computer (which needs to have Bluetooth as well), and a data plan for your cell phone (yes, ). The method below pairs your phone with your computer and connects them over a Personal Area Network (PAN). Here's How: • on your (usually found under the Settings menu) and set your phone to be discoverable or visible to other. • On the PC, find your Bluetooth program manager (in, look under My Computer > My Bluetooth Connections or you can look for Bluetooth devices in the; on a Mac, go to System Settings > Bluetooth). • In the Bluetooth program manager, select the option to add a new connection or device, which will make the computer search for available Bluetooth devices and find your phone. • When your cell phone appears in the next screen, select it to connect/pair it to your laptop. • If prompted for a PIN code, try 0000 or 1234 and enter it on both the when prompted and your computer. (If those codes don't work, look in the information that came with your device or do a search for your phone's model and the words 'Bluetooth pairing code'.). • When the phone has been added, you will be asked what service to use. (Personal Area Network). You should then have a working Internet connection. Tips: • If you can't find the Bluetooth program manager, try looking under Programs > [Your Computer Manufacturer's Name] > Bluetooth, as your system may have a special Bluetooth application. Aug 17, 2011. Whether you want to stay safe on the road or you've just got a really heavy phone, a Bluetooth headset can be a convenient addition to your cellphone. Here's how to set one up. Get the manual out for your Bluetooth device and follow the instructions there. Usually you will have to go to the Bluetooth option in your phone. Bluetooth® is a short-range communications technology that allows you to connect wirelessly to. Tips & Tricks: Setting Up Bluetooth on Your. • If you aren't prompted on your laptop for the type of service to use with your Bluetooth phone, try going into the options menu of your Bluetooth application to find that setting. • If you own a BlackBerry, you can also try the step by step guide to or my USB- and Bluetooth-friendly What You Need: • Bluetooth-enabled cell phone • Bluetooth adapter (built-in or ) for your laptop • Data plan from your mobile provider. ![]() This tip is only for devices running webOS 2.x When you activate a webOS 2.0 device, the first thing the phone does is search for a cellular signal or SIM card (for GSM phones). Even if you have an active Wi-Fi connection, if it is not an active device on your cellular account you will not be able to do much more than just turn the phone on. If your device is a GSM device and you have a friend with an active SIM card you can borrow, you should see if you could borrow it to activate your device and then take the SIM card out. If not, the good news is that unlike, you no longer need to download a program and connect your device to a computer to bypass activation in webOS 2.x. HP/Palm added in functionality so all you need to do is type in a code into the dialpad using the keyboard from the Device Activation Screen. For GSM devices, type #*DEVMODE# (#*3386633#) into the dialpad and then press the 'call' button. For CDMA devices, type ##DEVMODE# (there is no need to press the silver/Option key to access the symbols, and once you type #* or ## into the physical keyboard, the dialpad will automatically appear). The Developer Mode app will load up. Just turn it on and your phone will reboot into a bypassed activation mode. Unfortunately, the limitations described in our still applies for webOS 2.x phones. But we do have a few ways to get around this issue, although the end result will differ slightly if you have a GSM or CDMA device. Once again, you are better off borrowing a SIM card to activate your GSM device if that is available to you. Just like in our 1.x tip, once your device reboots, you will need to plug your device into a computer, select 'Just Charge' and load up webOS Quick Install. Then follow the following steps after the break. • Log on to a Wi-Fi network • Install Impostah from the app feeds in webOS Quick Install • Open Impostah, and select the 'Activation' button. ![]() • Choose your country and language, and then either enter your existing Profile email address and Password and select 'Log in To Profile' or provide a new address and password and 'Create Profile' • You should get a confirmation of success that your profile has been activated on that device. • You are now logged in to your profile and have full access to the App catalog. However, just as when you log in to a bypassed device on webOS 1.x, your apps and Profile-related data will not automatically redownload. If you have a CDMA device (this won't for for GSM devices) you can get around this using Impostah one more time. • Go back to the main Impostah screen and select 'Palm Profile' • From within the 'Palm Profile' section, choose 'Reset Palm Profile'. Accept all the warnings and proceed with the deletion. • This will perform the equivalent of 'Erase Apps and Data', except that it will maintain your Wi-Fi connection. • Your device will reboot back to the Profile Activation screen. However, you should still be connected to the Wi-Fi network • Log in to your profile, just as you normally would. If you get an error saying that it can not access the profile, try a few times (I had to try 3 times before my phone worked) Once you complete the activation steps and enter your synergy account passwords, your device will load up as if it was activated with a cellular account. Apps will be redownloaded, profile data will be restored, and the App Catalog will be available to you. This is the new Palm Pre activation video. Apparently, this is what a new user will see when they first start up their new Palm Pre. Palm has taken some serious. Hi webOS Nation, I recently bought a Sprint Palm Pre off of Ebay and wanted to use it over wifi, but when I turned on the device it wants me to make a. Mar 18, 2014 This technical overview for the IT professional describes the volume activation technologies in Windows operating systems and how your organization can. ![]() UVA Microsoft Agreements How to Activate Your Microsoft Software at UVA Microsoft Software Activation Instructions Some Microsoft products — Windows, Windows Server, and Office for Windows — require an online activation. UVA provides an online Key Management Service (KMS) that performs that activation. KMS activated software needs to periodically make contact with the KMS server to remain active — at least every 180 days (this happens automatically for computers connected to the UVA network). The KMS activation process is only intended for software downloaded through the Microsoft Campus/Enrollment for Education Solutions (EES) Agreement for University-owned computers. (Learn more about UVA Microsoft activation processes, including.) Activation Instructions • How to activate your Windows operating system: • • • How to activate your Microsoft Office: • • How to Activate Your Windows Operating System Windows 8/10 and Server 2012 Activation • Connect your computer to the UVA network (if on Grounds, via a or; if remotely, via the ). • Verify your computer has the correct date, time, and time zone (Eastern). • On Windows 8/Server 2012, move the mouse to the top right corner of the screen. A vertical toolbar appears, the Charms bar. Click on the magnifying glass icon, which is Search. On Windows 10, click into the Search bar on the Start bar. • When the Command Prompt icon appears, right-click on it. • A horizontal toolbar appears. Click on Run as administrator. • Click the Yes button on the dialog window that appears. • The path (e.g., C: Windows system32) should contain the word “Windows” and not “Users”. If it contains “Users”, close the window and repeat the two previous steps, being sure to open the Command Prompt as an administrator. • Copy and paste (or type) the command slmgr.vbs /skms skms.eservices.virginia.edu and press the Enter key. • Either “Key Management Service machine name set to skms.eservices.virginia.edu successfully” or an error message will be returned. • If not successful, ensure you typed the command correctly. ![]() There is a space between slmgr.vbs and /skms and between /skms and skms.eservices.virginia.edu • Copy and paste (or type) the command slmgr.vbs /ato and press the Enter key. • Either “Product activated successfully” or an error message will be returned. If you receive an error, contact the. • • Exit the Command Prompt window by typing exit followed by pressing the Enter key. • If you are at the Start screen, which is covered with tiles, click on the Desktop tile. • In Desktop mode, which looks similar to Windows 7, move the mouse to the right corner of the screen. A vertical toolbar appears, the Charms bar. Click on the gear icon, which is Settings. • Click on PC info and look to see what appears in this area. • You should see “Windows is activated.” If you see “Product Activation Required” instead, contact the for assistance. • Windows 7 and Server 2008 R2 Activation • Connect your computer to the UVA network (if on Grounds, via a or; if remotely, via the ). • Verify your computer has the correct date, time, and time zone (Eastern). • Navigate to Start, then All Programs, then Accessories. • Right-click on the Command Prompt icon and click Run as administrator. • Click the Continue or Yes button on the dialog window that appears. • The path (e.g., C: Windows system32) should contain the word “Windows” and not “Users”. If it contains “Users”, close the window and repeat the two previous steps, being sure to open the Command Prompt as an administrator. • Copy and paste (or type) the command slmgr.vbs /skms skms.eservices.virginia.edu and press the Enter key. • Either “Key Management Service machine name set to skms.eservices.virginia.edu successfully” or an error message will be returned. • If not successful, ensure you typed the command correctly. ![]() ![]() There is a space between slmgr.vbs and /skms and between /skms and skms.eservices.virginia.edu • Copy and paste (or type) the command slmgr.vbs /ato and press the Enter key. • Either “Product activated successfully” or an error message will be returned. If you receive an error, contact the. • • Exit the command prompt window by typing exit followed by pressing the Enter key. • Click the Start button. • Right-click on Computer and click Properties. Under Windows activation: • You should see “Windows is activated.” If you see “Product Activation Required” instead, contact the for assistance. • How to Activate Your Microsoft Office Office on a Windows 8/10 Computer • Connect your computer to the UVA network (if on Grounds, via a or; if remotely, via the ). • Verify your computer has the correct date, time, and time zone (Eastern). • On Windows 8, move the mouse to the top right corner of the screen. A vertical toolbar appears, the Charms bar. Click on the magnifying glass icon, which is Search. On Windows 10, click into the Search bar on the Start bar. • Using Search, determine the version (32-bit or 64-bit) of both the Microsoft Office software and the Windows operating system software installed on your computer: • For Office: Launch an Office application such as Microsoft Word by typing Word, and when the Word icon appears, click on it. Then click on the blank document icon to launch the program. Navigate to File, then Account. Click on the About Word icon to see the version listed at the top at the end of the first line of text in the dialogue box. Exit the application. • For Windows: If you are using Windows 8, open the Charms bar, click on the magnifying glass icon, and type computer. If you are using Windows 10, click into the Search bar on the Start bar and type computer. When the Computer icon or This PC icon appears, right-click on it, and when the horizontal toolbar appears, click Properties. The operating system version will be listed on the right under “System.” Close this window. • On Windows 8, move the mouse to the top right corner of the screen. A vertical toolbar appears, the Charms bar. Click on the magnifying glass icon, which is Search. On Windows 10, click into the Search bar on the Start bar. • When the Command Prompt icon appears, right-click on it. • When the horizontal toolbar appears, click Run as administrator. • Click the Yes button on the dialog window that appears. • The path (e.g., C: Windows system32) should contain the word “Windows” and not “Users”. If it contains “Users”, close the window and repeat the two previous steps, being sure to open the Command Prompt as an administrator. • Copy and paste (or type) the command from the table below that corresponds to your version of Office and Windows (as determined in Step 4 above): Microsoft Office Office Version Windows Version Use This Command. UVA Help Desk: 434-924-HELP (434-924-4357) • [email protected] Page Updated: 2017-01-01 © 2017 by the Rector and Visitors of the University of Virginia. The information contained on the University of Virginia’s Department of Information Technology Services (ITS) website is provided as a public service with the understanding that ITS makes no representations or warranties, either expressed or implied, concerning the accuracy, completeness, reliability or suitability of the information, including warrantees of title, non-infringement of copyright or patent rights of others. These pages are expected to represent the University of Virginia community and the State of Virginia in a professional manner in accordance with the University of Virginia’s Computing Policies. FileFixation.com is a new file sharing web service which gives you access to literally hundreds of thousands of direct downloads including software, games, movies, tv shows, mp3 albums, ebooks and more! Our downloads database is updated daily to provide the latest download releases on offer. Oct 27, 2011 pls send me autocad 2006 activation & serial code my id is. Can you give me the activation code and possibly serial number for autocad 2006 with request code. ![]() ![]() To celebrate our launch we are offering unlimited full download access for FREE! This is a limited offer and will soon expire and revert back to the normal member price. We now have 385,762 downloads in the member section. Take the FileFixation now for more detailed information! ![]() The word 'crack' in this context means the action of removing the copy protection from commercial software. A crack is a set of instructions or patch used to remove copy protection from a piece of software or to unlock features from a demo or time-limited trial. There are crack groups who work together in order to crack software, games, etc. If you search for Autodesk Architectural Desktop 2007 Crack, you will often see the word 'crack' amongst the results which means it is the full version of the product. The word 'serial' means a unique number which identifies the license of the software as being valid. All retail software uses a serial number or key of some form. The installation often requires the user to enter a valid serial number to proceed. A serial can also be referred to as a 'CD Key'. When you search for Autodesk Architectural Desktop 2007 Serial for example, you may find the word 'serial' amongst the results. This usually means your software download includes a serial number of some sort. The word 'keygen' means a small program that can generate a cd key, activation number, license code, serial number, or registration number for a piece of software. KeyGen is a shortened word for Key Generator. A keygen is made available through crack groups free to download. When writing a keygen, the author will identify the algorithm used in creating a valid cd key. Once the algorithm is identified they can then incorporate this into the keygen. If you search a download site for Autodesk Architectural Desktop 2007 Keygen, this often means your download includes a keygen. ![]() On Tuesday, February 4, 2014 10:54:46 PM UTC+5:30, wrote: > i need to now the activation code of cadd 2006 plzzzz i need to get activation code plzzzz can i can get it > > thanks.:) well its in torrentz site. Type autocad 2006. It has key generator. Type you serial key to install autocad and once you open after installation you can see your request code.copy the request code and paste it in key generator.it generates your activation code.enjoy:-) [email protected] 11:38. On Friday, July 27, 2012 10:31:48 PM UTC+8, mamata wrote: > On Friday, July 13, 2012 5:18:16 PM UTC+8, (unknown) wrote: > > > Please give me your mail id. Then I'll forward the keygen file. > > > > > > > > need the keygen also pls mail me hi there im also looking for activation code of autocad 2006 Product: AutoCAD 2006 Serial number/Group ID: 14 Request code: Y59D DWKH JRRA RX99 1JDC 55WT X2PT do you have an activation code for this one? [email protected] 17:47. On Friday, July 13, 2012 2:15:42 AM UTC-7, wrote: > Hi Manjesh, > > I have the keygen. I generate the 'activation code' using the keygen. Please try the below code and let me know. > > D396 TWZP D1AE E6A1 > > Thanks, > Sree Hello, I know this message is like 2 years after all these posts, but I have just acquired AutoCAD Mechanical 2006 and after the 30 day period ended, I can no longer use the software without actually activating it. Do you still have the keygen software? If so, my serial number is 39 and the request code is Z7QF 7TXU 06KQ Q47J 6XZ2 39W1 N079. Can you send me the keygen file if possible? [email protected] 12:54. On Wednesday, October 26, 2011 at 8:42:16 PM UTC-5, Mike wrote: > Does anyone still have a working/virus free keygen for AutoCAD 2006? > I'd like to get an activation code for > AutoCAD 2006 > Serial: 1 > Request Code: KK8X 3HQT 7WCY 1T5P S7DQ UW87 NAS0 I have the same problem. Why is it that any time I get a GenKey it ALWAYS has a Trogen attached? Someone want to help out with this: Product: AutoCAD 2006 Serial number/Group ID: 48 Request code: PA2S DWZV 0TNP XCWT 1S5S 6GWE 96FV F5CZ [email protected] 19:21. I need an activation code for autocad 2006 pliz serial no. 14 -- Masinde Muliro University of Science and Technology| P.O Box 190 - 50100, Kakamega, Kenya Tel: 056 31375| Email:| Website: ------------------------------ DISCLAIMER: *This email is confidential and intended for the sole use of the individual or entity to which it was addressed. If you have received this email in error please notify the sender immediately and delete this email without disclosing, copying, using, distributing or storing its contents. Kindly note that unless expressly stated, any views or opinions presented in this email are solely those of the author and do not necessarily represent those of Masinde Muliro University of Science and Technology. The recipient should check this email and any attachments for the presence of viruses. The University does not accept liability for any damage caused by this email* ------------------------------ [email protected] 03:25. On Wednesday, October 26, 2011 at 6:42:16 PM UTC-7, Mike wrote: > Does anyone still have a working/virus free keygen for AutoCAD 2006? > I'd like to get an activation code for > AutoCAD 2006 > Serial: 1 > Request Code: KK8X 3HQT 7WCY 1T5P S7DQ UW87 NAS0 Monday, Nov 9, 2015 Terry wrote. Product: AutoCAD 2006 Serial number/Group ID: 14 Request code: rp53 dsrd g892 kagt 89uq 053q y7t0 plz send me an activation code, thanks, send to Thanks.T [email protected] 07:48. On Friday, July 13, 2012 at 4:15:42 PM UTC+7, wrote: > Hi Manjesh, > > I have the keygen. I generate the 'activation code' using the keygen. Please try the below code and let me know. > > D396 TWZP D1AE E6A1 > > Thanks, > Sree Dear Sir, Could you please generate the activation code for me, following are the details: Product: AutoCAD Electrical 2006 Serial number/Group ID: 14 Request code: YZSF T07J 9N36 J1WT HC6F C318 ENTJ 99FW Thankyou for your kindness, God Bless You. Yudi [email protected] 01:05. December 2004 Please read this documentation carefully. It includes late-breaking information about Microsoft Windows XP Embedded that became available after the product documentation for Windows XP Embedded was written. The information in this document has precedence over the information included in the online Help installed with the product. Unless stated otherwise, all information included here applies to this version of Windows XP Embedded. For the most up-to-date Release Notes, see this. Contents Hardware Requirements Development and Target System • The system requirements for Windows XP Embedded have changed from those documented on the product box. Use the following disk size requirements to install Windows XP Embedded: • Development tools only: 200 megabytes (MB) • Development tools and database on the same system: 3.2 gigabytes (GB) • Shared component database in a team environment: 3.2 GB • Windows XP or Windows 2000 with Service Pack (SP) 2 or later, or Windows Server 2003, is required before you install Windows XP Embedded. For more information about the hardware requirements, see the Installation Guide, located on the distribution medium, or the Getting Started Guide, which is available on your development system after installation. Installation Upgrading from either Windows XP Embedded with Service Pack 2 Beta or a release candidate (RC) is not supported. If you have Windows 2000 SP2 installed, you must install the latest version of the Windows Script Host before you install Windows XP Embedded with SP2. To do this, navigate to the MSDN Web site, and then search for the latest version of this update. ![]() ![]() For information about installation and configuration options, see the Installation Guide located on the distribution medium. During the installation of the Windows SP2 database update, the machine may appear to be hung or stopped. The dialog box displayed may also appear unresponsive. This is normal behavior, and is caused by the sheer volume of data the installer is processing and applying to your database. The entire installation process may take between 15-30 minutes to complete, with significant portions of that time consumed by internal processing. The ewfapi.lib that is included on the installation media is an incorrect version. Screensaver Launcher activate your default screen saver from the. Stay on top of the latest XP tips and tricks with our free Windows. Enables desktop screen savers. If you disable this setting, screen savers do not run. Also, this setting disables the Screen Saver section of the Screen Saver dialog in the Personalization or Display Control Panel. As a result, users cannot change the screen saver options. Apr 25, 2007. I am a proud user of Windows XP. Not quite as cool as Linux, but hey, it's a family computer, and Windows is more widely used. Thus far I've only had one problem with it, my son put a password on the screensaver! Which doesn't bother me, because I know how to turn it off. My question to you is, how do I. Information about Windows XP, Vista, Windows 7 and 8 including tweaks, slipstreaming, install, registry. Enable/Disable Logon Screen Saver. More Activate Screensaver Xp images. The correct version is available as a QFE from. Setup Program During the Windows Embedded Studio tools and database setup, if you type the run-time product key instead of the tools and database product key, the Setup Wizard will not allow you to continue, even if you later type the correct product key. If this occurs, exit, and then run the Setup Wizard again. Be sure to use the tools and database product key. Database and Repositories • The SP2 database update fails if the Windows Embedded Studio is not installed on the same machine. • If you remove Windows Embedded Studio and then try to run database engine setup, you may get the following message: 'Setup failed to configure the server. Refer to the server error logs and setup error logs for more information.' This message may appear if you removed Windows Embedded and then tried to reinstall the Microsoft SQL Desktop Engine (MSDE). Remove or rename the Data folder, typically found in 'C: Program Files Microsoft SQL Server MSSQL.' Then try installing the database engine again. • Uninstalling the database will remove all components imported into that database. After reinstalling the Windows XP Embedded database, additional components needed or referenced in an.slx or.sld file must be reimported into the database or these files may not open correctly. • You must install repositories on the same computer on which you are planning to install the database. • When a network connection is not available, the repository paths must be changed from network shares to local paths. To change the repository paths, use the following procedure: • Exit all Windows Embedded Studio applications. • Exit all Windows Embedded Studio applications. • Run Component Database Manager. • Select the Repositories tab. • For each repository: • Select the repository. • Choose Change Location. • Change the MachineName/ShareName from a network path to a local path. • Verify that the Move repositories to the new location check box is cleared. • Dual installations of the database are not supported, whether on the same or different drives or partitions. Windows Embedded Studio • When adding resource extended properties that are formatted as multistring types, do not exceed 3850 characters in the Value field. • If you specify an invalid log file when importing a file using the Import File dialog box, the import fails and the following message appears. File import failed due to unspecified error while processing file (). You must cancel the import, and then try again using a valid log file. Target Designer • Run-time images must be placed in the root directory of the boot partition on the device. There must not be any other operating system on the boot partition that could conflict with the Windows XP Embedded image. • Some Start menu shortcuts are broken. Links to features, such as Activate Windows, Tour of Windows XP, Imaging, System Information, and CD Player, will not operate correctly because these features are not included in Windows XP Embedded. These links are provided by the Standard Start Menu Shortcuts component. You can disable these in the resources node of that component in Target Designer. • After building a configuration, if you manually inspect the run-time hives using RegEdit, you cannot build an image in that folder again until you unload the hives, and then exit and run Target Designer again. Target Designer will display a message that you cannot clear the contents of the destination folder even though the destination folder may be empty. • Setting cmiUnjoinDomain = 'FALSE' in system cloning in Target Designer does not retain setting on reseal. To work around this issue: • Go to Start and select Run. • In the Run dialog box, enter the following command: Windows System32 fbreseal –keepdomain See this for more details. • Running Target Designer on Chinese (PRC), Chinese (Taiwan), or Korean development machines may result in a script error when building a configuration with the Speech API Core component. If this component is required for your configuration, build the configuration from a development machine set for any other language. If the Speech API Core component is not required, you can ignore the error. • Some components require the selection of other components that have a visibility as low as 100. To view these additional components, you must lower the visibility in Target Designer to 100 and keep the visibility set to 100 throughout the life of the configuration. This is also true for any other development system that will host these configurations. The following components must be altered as indicated: • The Map Network Drive/Network Places Wizard component requires you to manually add the Primitive: MPRUI and Msxml Libraries components. • The Terminal Services Web Control Extensions component requires you to manually add the Terminal Services Web Control Core component. • If you add a prototype component to a configuration, you will receive a CMI error that the prototype does not contain a valid cmiLangID property and you will not be able to build a run-time image. Prototype components should not be manually added to a configuration with Target Designer. • You cannot make copies of components from a configuration and then add multiple instances of that component to the same configuration. To add multiple instances of the same component to a configuration, use either a drag-and-drop operation or double-click the component for each instance you want to create. You can also copy a component instance, including its settings, and then add it to a second configuration if that component does not already exist in the second configuration. • If you are using a complex filter, the following error message may appear. The CMI encountered the following error: 0x80042335 (-) A database error occurred within the CMI. To resolve this issue, add the HKEY_LOCAL_MACHINE SOFTWARE Microsoft Windows Embedded CMI DBCmdTimeout registry key. You can then create the DBCmdTimeout DWORD and set the value to 300, which is five minutes. If the error occurs again, or if you are using a more complex filter algorithm, you may need to increase the DBCmdTimeout value. • If Target Designer displays a script error while shutting down, you can safely ignore the error message. • A Text Services framework cannot be configured within Target Designer, but can be managed from Control Panel on the device at run time. • To ensure that locale settings are applied to a run-time image, you must use the extra files in Target Designer to add%windir% system32 Winnls.dll to your configuration. • When a dependency check is run, the log file will occasionally truncate the last few characters of the report. • Upgrading a configuration enables all previously disabled components. This can cause your run-time image size to increase. To work around this issue: • Find the re-enabled components immediately after the upgrade • Disable these components before running a dependency check to avoid a run-time image size increase. • Once the component browser or output panes are undocked, they cannot be docked again by dragging them to their original locations. To dock them, you must double-click their title bar. • When browsing a run-time image, you may notice that there is a system identifier associated with all files and folders. This is expected behavior and can be ignored. • When the operating system is increasing the pagefile size to allow allocation of more memory, Target Designer may display a message that not enough storage is available to complete this operation. Perform the same operation again after the operating system finishes increasing the pagefile size. Component Designer • If you add file resources using the Add File, Multiple Files, or All Files in Folder option, the effective path of the files will not automatically be converted to directory identifiers (DIRIDs) if the source file location is on a network share, different partition, or separate physical disk. The absolute path of the file is inserted instead of the DIRID and must be manually converted from the absolute paths to the correct DIRID. • When importing.inf files to create components, Component Designer may not correctly parse file resources referenced as strings. You must manually author these resources if they are missing after the import completes. Target Analyzer • To produce a starter configuration in Target Designer, the Logical Disk Manager component is added to the configuration. However, it is not critical to boot the system and may be removed to reduce footprint. • The Target Analyzer probe file, Tap.exe, may report hardware devices that are no longer in your system. You should manually remove these devices from the configuration before building a run-time image. • Target Analyzer does not detect infrared devices. To enable infrared support, add the Built-in Infrared Device component. Device Update Agent • Device Update Agent (DUA) requires that the binary data for REG_BINARY in the update script (.dus) file be in decimal format instead of hexadecimal. When data is exported from the registry, or Win32 API calls are made to query registry values, the data returned is in hexadecimal format. You must convert the hexadecimal-formatted values to decimal in order for DUA to apply the REG_BINARY value. • You need to manually include the TCP/IP Networking component so it can poll an HTTP server. • Do not leave the Working Directory field blank in the Device Update Agent component settings. Leaving the working directory blank will cause a build error and make DUA not work correctly when the run-time image is booted. • Do not set update program (.dup) file attributes to read-only. When DUA attempts to parse a read-only.dup file or parse a.dup file from a read-only local folder, it will fail to execute any commands in the file. If the.dup file is read-only, DUA will also leave behind a copy of the.dup file in the local DUA working directory. DUA can correctly parse.dup files that are stored in a read-only remote share (UNC path). • In order to use proxy settings, Proxy Access Type must be set to 3. • Selecting the Administrator Service Account causes the DUA service to not start without user intervention. From the run-time image, open the DUA service in Services.msc and manually set the password for the administrator account. • DUA deletes the.dup file after consuming it in local polling scenarios. To work around this issue: DUA can correctly parse.dup files that are stored in a read-only remote share (UNC path). • Specifying a password causes build errors. If you need a user name and password for polling, use the following procedure: • Type a user name in the User Name field of the Device Update Agent component settings. • Leave the Password field blank. • Set the HKEY_LOCAL_MACHINE System ControlSet001 Services DUAgent Parameters Config Sessions 0000 registry key value as the password for polling. The type should be either REG_SZ or REG_EXPAND_SZ. Remote Boot Service • If a Preboot eXecution Environment (PXE) client attempts to download an image that is too large to run in memory, the following error message is displayed: 'Windows could not start due to an error while booting from a RAMDISK. Windows failed to open the RAMDISK image.' This error means that the client computer does not have enough RAM for the current RamDisk image to run. Component Issues • Allowing auto-resolve to add Windows Logon to a runtime causes the automatic logon default username to be overwritten. • If you configure the Legal Notice text setting in Windows Logon (Standard) component with several lines of text, no scroll bars appear during boot, which prevents the user from reading the entire End-User License Agreement (EULA). • Minlogon runtimes fail to system restore. • Use the XPePM.exe tool to change the system power state only if you are deploying a minimal kernel-only image. XPePM.exe does not implement all the steps necessary to shut down or standby a Minlogon- or Winlogon-based image. Instead, use such exiting Windows functions as ExitWindows[Ex], InitiateSystemShutdown[Ex], or SetSystemPowerState. • The User Interface core component setting cmiShowAccessories can only be set by means of the Advanced button. • In the User Interface core component, disabling Show context menu on files and folders causes the Explorer task pane to behave erratically. • Changing the following display adapter attributes to a value not normally shown in the configuration list will cause a script error: • cmiColorQuality • cmiScreenRefresh • You may receive an access violation - code c0000005 when issuing the command netsh bridge show adaptors in Windows XP Embedded images. • Some component Help topics may include dependencies to end-of-life components. These end-of-life components do not include component Help topics and appear as broken links. Dependency Issues • File sharing requires Windows Firewall and its associated dependencies to be present. So as part of footprint reduction, if you do not go with the default settings when using the Core Networking component and instead configure your image so that it does not bring in Windows Firewall, there is a known issue of the command net start lanmanserver giving error 126 (the specified module could not be found). This is due to the missing dependency on Hnetcfg.dll, which is part of the Windows Firewall component. • Adding the Windows Firewall component to your runtime but not including the Windows Firewall Control Panel component may present a user with the RunDLL error 'Unable to locate firewall.cpl.' You should either add the Windows Firewall Control Panel component to your configuration, or unblock the necessary applications within the Windows Firewall component. • Notifications of Bluetooth events like bonding, connection over PAN, and new device, do not appear unless the Tray Icon Add/Remove Support component is added to the runtime and the Show Notifications on Task bar check box is selected in the User Interface Core component settings. • Runtimes that include the Microsoft System Management BIOS Driver Installer component are missing a dependency to the WMI Win32 Provider component. • If you do not use the El Torito CD Support macro component to build an El Torito configuration, you will have to manually add the CDFS component to your configuration. • To change the screen savers on the runtime, include the Display Control Panel component in your configuration. • The User Account control panel behaves erratically if Help files are not included in the runtime. To include help files, access the base component's Other Settings section and clear Do not copy help files for this configuration. • The Communications Port component is missing dependencies on the Plug and Play Software Device Enumerator and PnP (User-mode) components. • Service Control Manager (SCM) component dependencies are missing in some components that require SCM and may not automatically be added to the configuration as part of dependency checking. If this occurs, you should manually add the Service Control Manager (SCM) component. • To enable USB printer support, add the Primitive:Win32spl component. • The Add Printer Wizard will not work unless the Unidrv.hlp file and all printer-specific.hlp files are present. This also affects Bluetooth printers that are dynamically discovered in the field. To reduce the run-time footprint, you will need to adjust your global settings to include Help files, and then clear the Help inclusion option for all unwanted Help in the configuration. • For the FBA to bind TCP/IP to a 1394 adapter, you must add the PnP User Mode component. • The Home Gateway and Kiosk/Gaming macro components do not contain the Dialer Application component necessary to dial a phone number. You must manually add this component, or you must use a third-party application to enable this feature. • The following components are only supported when used with the Windows Logon Standard component: • Japanese Input Method Editor (IME) components • Utility Manager component accessibility features • Default presentation setting for the power policy in the Computer component • Hotmail through MSN Explorer • If your embedded run-time image is based on the Minlogon baseline configuration and you add the System Cloning Tool component, you must also ensure that your configuration includes the Local Security Authority Subsystem (LSASS) and TCP/IP Networking components. To locate the LSASS component in Target Designer, you must first set visibility to 200 or lower. • If you add the Local Network Bridge component in your run-time image, add the Connection Manager Runtime component. • The route argument (-r) in the NetStat command does not work properly unless you manually add the Route.exe file in your configuration. • If you add the Software Installation Group Policy MMC Snap-in component to a configuration, add the NLS: Time Zones component. • When adding the Windows XP Explorer User Interface component to a configuration, a dependency check may reveal that it contains a dependency on at least one format utility. You can disregard this dependency. • If you add the Remote Registry component to a configuration, add the RPC Remote over Named Pipes component. • If you add the RPC over Named Pipes component to a configuration, add the server service. • User account pictures in the Users program in Control Panel will not appear unless you add the Windows Picture and Fax Viewer and Images and Media components. • The ICM User Interface component requires the Display Control Panel component to enable you to select color profiles at run time. • To enable full graphical user interface (GUI) functionality for the Users program in Control Panel, add the Administration Support Tools component in your run-time image. • Some.chm files require the Help and Support Services component. If you use one of these files and do not add this component to your configuration, script error messages may appear. • If you add the Windows Movie Maker component to a configuration and want to use video recording features, add the DirectX9.0c Macro component. • Help files are not available and do not launch when the HTML Help Engine component is added to a configuration unless you manually add the Primitive: Winhelp32 component. • Desktop wallpaper preview will not function unless you add the Windows Picture and Fax Viewer component. • The Troubleshooters component requires the Help and Support Services component. • If you add the NetBIOS Driver component in a configuration, add the PnP (User-mode) component. • The ASP.NET 1.1 component is missing a dependency on the IIS Web Server component. • Context-sensitive Help in the Windows Explorer shell requires the Primitive: Winhlp32 component. • If you add the Error Reporting component to a configuration, add the Terminal Services Macro component. • If you add the Serial Input Support component to a configuration, add the Accessibility Control Panel component. • If you add the Internet Connection Discovery Client component to a configuration, add Hnetcfg.dll as an extra file. • If you add the Microsoft Management Console (MMC) component to a configuration, add the MSXML 3.1 component. • If you add the Search Assistant User Interface component, add the MSXML 3.1 component. The search pane is not centered correctly because the animated character cannot be rendered on a Windows XP Embedded system. To center the pane, choose Change preferences, and then choose Without an animated screen character. • You should always use the Internet Information Services Technologies (IIS) macro component. If you require the Internet Information Services and printer management using Active Server Pages (ASP) components, manually add the Printing (Server/Shared) component to the configuration. Windows cannot find '/idlist,:2712:1964,D: Documents'. To resolve this issue, add the Explorer Shell component. Upgrade Issues • If you upgrade Language Support components, they will lose their settings. • If you upgrade the User Account component, the User Account component names are changed. Actual account name/user name and any other configurable settings for this component are not changed. File Issues • The Display Control Panel DPI settings in the advanced properties of the Display Control Panel are grayed out. To work around this issue: • Copy Font.inf from the repository to the%WINDIR% INF folder. -or- • Add International Control Panel to the configuration. • If you add the Oledb Provider for Internet Publishing component in a configuration, run Regsvr32 from Program Files Common Files System OLE DB Msdaipp.dll at run time. • To enable full functionality support of Message Queuing (MSMQ) COM Library and Message Queuing (MSMQ) DCOM Library components, register Mqoa.dll by creating an FBA COM/DLL registration resource or by running the command RegSvr32.exe Mqoa.dll from the command line. Failure to register Mqoa.dll will have an impact on applications using IDispatch, such as Microsoft Visual Basic Scripting Edition (VBScript) programming language and Active Server Pages (ASP). • Some components reference Capi20.sys, Serial.vxd, and Dmicall.sys, which do not exist in Windows XP Professional or Windows XP Embedded. Resulting errors can be safely ignored. • When accessing Movie Maker Help, an error message appears stating that the Help file cannot be found. This occurs because the Help file was placed in the MUI 1033 folder instead of the MUI 0409 folder. • Creating desktop shortcuts to MS-DOS programs is not supported. To resolve this issue, add Apps.inf, which is located in the repository to the Windows/INF folder, to your image. This will allow you to create shortcuts to MS-DOS programs. Shortcuts to MS-DOS programs will then have a generic icon instead of the MS-DOS icon. • For direct cable connections to work properly with the Unimodem component, you must move the Rootmdm.sys file from the Windows System32 (%11%) folder to the Windows System32 Drivers (%12%) folder in the run-time image or on the target system after booting the run-time image. Terminal Services Issues • The Terminal Services core component has a default setting to allow users to connect remotely to the computer. It should be disabled unless this functionality is needed and all users have strong passwords. • The initial attempt to copy folders from the Terminal Services Client to the Terminal Services Remote Desktop fails. Subsequent attempts to copy should operate correctly. • For users to connect remotely to a computer, the user account must have a password. Windows Firewall will be configured to allow remote desktop connections to this computer. First Boot Agent • When First Boot Agent (FBA) completes, it will reboot the device without notification. This is expected behavior. • A cloning process (that is, SysPrep) fails to restart MSDTC service when other services have started or are starting. In order to restart MSDTC and IIS, enter the following commands after cloning completes: • msdtc -install -a • msdtc -resetlog • iisreset /restart • If the runtime is on a partition other than C: and the runtime does not have the file system component for the file system on C: partition, you may receive the following error in the FBALog: '[FBAInstallSecurity] SCE Error: 0x4b8.' This error can be safely ignored as it means it was not able to read files on the boot partition. • Upon first boot into the runtime, there will be a Windows Product Activation (WPA) error in the Application log of the event log. This is a harmless error and can safely be ignored; it is a one-time occurrence and is not indicative of any WPA problem. It is due to the unique behavior that WPA has on Windows XP Embedded images. • The FBA log will show a harmless error if the Performance Counter Configuration component is included in a runtime. The log text is as follows and can be disregarded. [FBAApplySecurityStringToRegKey] RegSetKeySecurity Failed! Error: 0x6 [FBAReplaceSecurityInRegistry] FBAApplySecurityStringToRegKey(009) #1 Failed! • FBA refers to syssetup.inf located at%WINDIR% INF for installing devices or any DLLs during setup. Even though a component in a runtime might have a DLL/INF registration/installation file set at a particular phase, FBA gives precedence to syssetup.inf and installs the INFs and DLLs specified therein, if any. • The following error may appear during FBA. User Configuration Administrative Templates Control Panel Display Description Enables desktop screen savers. If you disable this policy, screen savers cannot run. This policy also disables the Screen Saver section of the Screen Saver tab in Display in Control Panel. As a result, users cannot change their screen saver options. If you do not configure this policy, it has no effect on the system. If you enable this policy, a screen saver will run if the following two condtions are true: First, a valid screensaver on the client is specified via the policy setting or through Control Panel on the client computer. Second, the screensaver timeout is set to a nonzero value via the policy setting or through Control Panel. Related Policies. I ran a repair on XP and after the repair I got a message saying that I needed to activate windows before I can log in.Choosing 'No' would send be back to the login screen and choosing 'Yes' would begin to load Windows, but only as far as showing me the desktop with no icons. I was able to fix this problem by starting the PC in safe mode with command prompt. I then typed 'explorer' into the command prompt to load Windows. Next I clicked on 'Start' - 'Run' and in the 'Run' box I typed 'Rundll32.exe syssetup,SetupOobeBnk'. This extended my activation to 30 days. Even though this extended my activation period, I was still unable to get the activation program to start up. I fixed that by going into 'regedit' and searching for the 'wpaevents' folder. I then changed the permissions to include 'User' for 'Full control'. I also went to my c: drive and changed the permissions to include 'User', 'Administrator', and 'System' for 'Full control'. I rebooted the machine and then was able to run Windows activation. I got all my info from. I used this method, and still get the wallpaper screen forever. ![]() I am working to recover an old computer which has had it's ethernet controller fail, as well as the internal wi-fi. I have attached a USB wi-fi adapter, and run the installation software in safemode. When I reboot, I still get the 'This copy of Windows must be activated with Microsoft before you can log on. Do you want to activate Windows now?' Right back to the wallpaper. This is the result of a Windows Repair, XP Home Edition SP3 Build 2600.xpsp.0 I have verified with Microsoft that the software is a legal copy, but they want $180 to talk me through validation. Thanks for any further suggestions •. ![]() Only Solution: Windows XP Logs You Off When You Try to Activate the Product -- Carey Frisch Microsoft MVP Windows XP - Shell/User Be Smart! Protect your PC! ----------------------------------------------------------------------------------------- 'R Doornbosch' wrote in message: news.| Can anyone explain to me how to activate XP after the 30 days has expired,| without re-installing XP. I have let the 30 days laps and this computer does| not have any internet access (NO Modem or network card). I also am not able| to log into XP. 'R Doornbosch' wrote in message news. > Can anyone explain to me how to activate XP after the 30 days has expired, > without re-installing XP. I have let the 30 days laps and this computer does > not have any internet access (NO Modem or network card). I also am not able > to log into XP. > > Login in Safe Mode (Press F8 during boot up) Then activate via telephone. -- Regards, Mike -- Mike Brannigan [Microsoft] This posting is provided 'AS IS' with no warranties, and confers no rights Please note I cannot respond to e-mailed questions, please use these newsgroups 'R Doornbosch' wrote in message news. > Can anyone explain to me how to activate XP after the 30 days has expired, > without re-installing XP. ![]() I have let the 30 days laps and this computer does > not have any internet access (NO Modem or network card). I also am not able > to log into XP. R Doornbosch wrote: >Can anyone explain to me how to activate XP after the 30 days has expired, >without re-installing XP. I have let the 30 days laps and this computer does >not have any internet access (NO Modem or network card). I also am not able >to log into XP. You should be able to login if you boot, hitting F8 as BIOS info goes to black (before the Windows splash) and take Safe Mode. There run Start - All Programs - Accessories - System Tools - Activate Windows and use the Activate by phone. You will need access to a phone (do *not* let the activation process close down until you have completed the call), call a toll free number that will be given and swap one long number for another to type in -- Alex Nichol MS MVP (Windows Technologies) Bournemouth, U.K. (remove the D8 bit). ![]() Mar 21, 2012 The 30 day activation window has passed. XP activation window expired. Markeby Mar 9. It currently has Windows XP pro SP3 installed. Tech blog The Tomorrow Times shows you how to gain access to your PC even if you've gone past the 30-day Windows activation period. |
AuthorWrite something about yourself. No need to be fancy, just an overview. Archives
March 2018
Categories |